Bulletin 1734 POINT I/O In-Cabinet Modular

Bulletin 1734 POINT I/O™ is ideal for applications requiring flexibility and low cost of ownership. Granularity of one to eight points lets you buy only the I/O you need. The compact design makes installation easier in limited panel space. The family includes POINT Guard I/O™ safety-rated I/O modules that can be used side-by-side in a standard POINT I/O system. Network connectivity includes ControlNet™, DeviceNet™, EtherNet/IP™, and other open networks. Some modules feature DeviceLogix™ Smart Component Technology, integrating low-cost logic solving capability in your I/O for faster sense-to-actuation times.

Features

  • Modular design lets you independently select the I/O, termination style and network interface
  • Components install easily by sliding together; pull apart easily for maintenance
  • Removable wiring system saves time and money during installation and troubleshooting
  • Comprehensive diagnostics and configurable features makes POINT I/O™ easy to apply
  • Removal and Insertion Under Power (RIUP) lets you replace modules while the system is in operation
  • Mount horizontally or vertically, with no de-rating required
  • Auto Device Replacement (ADR) lets OEMs add features and I/O with minimal effort
  • Add-On-Profiles in RSLogix 5000 programming software provide smooth integration into Integrated Architecture systems

Products

1734 POINT I/O Communication Interfaces

  • Provide the interface between the POINT I/O™ modules and backplane, and the desired network
  • Snap onto the DIN rail

1734 POINT I/O Terminal Bases

  • Consist of a I/O mounting base and removable terminal block (RTB)
  • Snap onto the DIN rail
  • I/O module plugs into the mounting base
  • RTB provides terminal connection points
  • Terminal bases plug into each other to form the system backplane

1734 POINT I/O Modules

  • Provide one to eight I/O circuits
  • Standard and safety versions available
  • Plug into a terminal base assembly on the DIN rail

1734 POINT I/O Power Supplies

  • Enable expansion of the POINT I/O system
  • Provide flexibility to mix a variety of signal types in the same assembly

1734 POINT I/O Accessories

  • Variety of products to complete the POINT I/O system
  • Include common and voltage terminal modules, replacement terminal blocks, and other products

Certifications

  • POINT I/O and POINTBlock I/O modules: CE, C-Tick, ODVA, ATEX
  • POINT Guard I/O™ modules: CE, C-Tick, ODVA, ATEX, TÜV-certified for functional safety up to and including SIL 3, Cat. 4, PLe

Certifications apply when product is marked. See our Product Certification site for Declarations of Conformity, certificates and other certification details.

Learn More

  • Our DeviceLogix Smart Component Technology integrates logic-solving capability into I/O, motor starters, push buttons, and other control components, delivering higher-performance and lower-cost distributed control.
  • Protect your people, productivity and environment with integrated Safety Solutions from Rockwell Automation. We understand your factory floor challenges and can help you meet your goals, using one of the broadest safety portfolios in the industry.
  • Rockwell Automation Integrated Architecture Solutions provide the foundation to drive plantwide optimization efficiently and effectively, enabling you to respond competitively to the economy and changes in consumer demand.

Communication Interfaces

Bulletin 1734 POINT I/O™ Communication Adapter Modules enable the POINT I/O modules to exchange data with an I/O scanner across a communication network. Communication adapters are available for EtherNet/IP™, ControlNet™, DeviceNet™, and other networks.

POINT I/O Modules

Bulletin 1734 POINT I/O™ offers digital, analog, and specialty I/O, as well as POINT Guard safety-rated I/O, with one to eight points per module. You can mix standard and safety I/O in the same system. Comprehensive diagnostics and configurable features make POINT I/O easy to apply.

POINT Guard I/O Modules

POINT Guard I/O™ modules are safety-rated I/O modules designed to fit into the standard POINT I/O™ system, offering automation and safety functionality in a maximum density I/O solution. POINT Guard I/O communicates by using the CIP™ safety protocol over EtherNet/IP™ for GuardLogix™ controllers or DeviceNet™ for SmartGuard™ 600 controllers.

Power Supplies

Bulletin 1734 POINT I/O™ power components expand the POINT I/O system and provide the flexibility to mix a variety of signal types.

Terminal Bases

A Bulletin 1734 Terminal Base Assembly consists of a mounting base and a separate removable terminal block (RTB). The base mounts on the DIN rail. The RTB plugs into the mounting base and provides the terminal locations for field wiring. The POINT I/O™ module plugs into the mounting base above the RTB.

Frequently Viewed Publications

TitleNumberLanguage
1734 POINT I/O Product Profile1734-PP001
1734 POINT I/O Selection Guide1734-SG001
1734 POINT I/O Installation Instructions1734-IN510
EtherNet/IP Embedded Switch Technology Application GuideENET-AP005
More 1734 POINT I/O Module publications in Literature LibraryAll Languages

Product Catalog

Find catalog numbers, certifications, and specifications.

Certifications

See our Product Certification site for Declarations of Conformity, certificates and other certification details.

Can’t Find What You Need?

Browse our Literature Library where you can search for additional publications in more languages. You can also use the Advanced Search feature to search by catalog number, publication type, title, or keywords to narrow your results.

Build This Catalog Number

Build or verify a catalog number, and get information and CAD drawings for these products.

Configuration & Selection Tools

Other Resources

  • Electronic Data Sheets — Find DeviceNet™, ControlNet™, EtherNet/IP™, and network-independent EDS files.
  • General Station Descriptions — Find PROFIBUS GSD files.
  • Knowledgebase — Visit our online resource for technical information, support chat and forums, software updates, and product safety advisories/notices.